Condensate Drains, Oil/ Water Separators,  Electronic Timers, Solenoid ValvesCondensate Drains, Oil/ Water Separators,  Electronic Timers, Solenoid Valves


Click the catalog
above to see Jorc
Industrial's Online
Catalog


2/2 & 3/2 VACUUM SERVICE

Closed when de-energised (NC)
* All FIG. links will take you to www.jorc.com site

Ports

Orifice size
[mm]

QNn-value
[l/min]
AIR

Minimum differential pressure
ABSOLUTE
[mbar]

Body

Seal

Mass
[kg]

Coil type

Model

Voltage

Order code

*Fig.

2/2 Closed when de-energised (NC)

3/8

7

800

15

Brass

NBR

0.52

TM35

D224

115VAC

320717

1

1/2

10

1600

15

Brass

NBR

0.57

TM35

D240

115VAC

340704

2

1/2

12

2500

15

Brass

NBR

0.43

TM30

M245

115VAC

340516

3

3/4

18

4100

15

Brass

NBR

0.76

TM30

M252

115VAC

350513

3

1

23

8800

15

Brass

NBR

1.20

TM30

M262

115VAC

360710

3

6/4

40

21000

15

Brass

NBR

2.75

TM30

M275

115VAC

370810

3

3/4

18

4100

15

Brass

NBR

0.66

TM30

M250

115VAC

350510

4

1

25

9000

15

Brass

NBR

1.20

TM30

M260

115VAC

360518

4

6/4

40

21000

15

Brass

NBR

2.40

TM30

M270

115VAC

370511

4

2

50

40000

15

Brass

NBR

4.50

TM30

M286

115VAC

390542

4

   
2/2 Open when de-energised (NO)
 

3/4

18

4100

15

Brass

NBR

0.66

TM30

M350

115VAC

359511

4

1

25

9000

15

Brass

NBR

1.20

TM30

M360

115VAC

369510

4

6/4

40

21000

15

Brass

NBR

2.40

TM30

M370

115VAC

379510

4

Other versions on request.

3/2 Closed when de-energised (NC)
 

1/4

4.5

470

15

Brass

NBR

0.52

TM35

D32NO/NC

115VAC

330742

5

Other versions on request.
 
TECHNICAL DATA
Internal parts: Stainless steel
Seals: NBR, FPM
Fluid temperature: 14 F to 194 F
Ambient temperature: 140 F max
Viscosity: 21 mm2/s max
Response times: closing 5 - 120 ms
Supply voltage: 230, 115, 48, 24 V 50/60 Hz
  24, 12 VDC
Power consumption: See chapter COILS!
Duty cycle: continuous (ED100%)
Cycling frequency: 250 - 800 cpm
Electrical protection: IP65 (with plug to DIN 43650)
  OPTIONS
  • EEx me II explosionproof coil

 


ORDERING
Please state Order code, Seal material and Voltage; Example: 320611 EPDM 24VDC, or contact us.

Specifications are subject to change without notice.
© 2003 All Rights Reserved, JORC Industrial